ISSUE
When PM60 WEH scans a barcode starting with '0', the starting 0 is not reading
ex) 0653437XXXXXX → 653437XXXXXX
APPLIES TO
PM60 WEH (Window Mobile)
RESOLUTION
Using Extended Wedge function, add 0 at the start of the decoding data.
Here is the scanner setting which allows you to capture barcode as expected.
Navigate to Settings > System > Scanner Settings
Click Wedge tab and enable Enable Extended Wedge check box, and then click Configuration
Go to Symbologies under Condition, and then check UPC-A only and click Save
Click Add new under Actions
Set as below and click Add
- Action: Send string
- Value: 0
Check if the result is decoded as expected