This article is preview version of RFID Configuration & Wedge. Log in to read the full version containing all configurations description. Contact Point Mobile team to get an account. |
Point Mobile RFID readers
Configuration | General | PM500 | ||
---|---|---|---|---|
Profile | O | X | ||
Beep Volume | O | |||
Vibrator | O | X | ||
Radio Power | O | |||
Tx Cycle | Tx ON duration | O | ||
Tx OFF duration | O | |||
Tx Data Format | O | |||
Data Format | O | |||
Filter duplicate tags | O | |||
Filter (1, 2) | Tag Pattern | O | ||
Offset | O | |||
Select | O | |||
Enable filter | O | |||
Inventory Config | Inventory Param | Session | O | |
Q | O | |||
Flag | O | |||
Link Profile | O | X | ||
Operation Mode | Mode | O | ||
Timeout | O | |||
Tag Focus | O | O | ||
Fast ID | O | |||
Continuous Read | O | |||
Auto Read | On / Off | O | ||
Auto read interval | O | |||
Save Log | O | |||
Save tag list to csv | O | |||
Sleep | O | X |
Set time it takes to read again the tag which is read once. (Time to move back to A after the inventory flag changes from A to B.)
Options:
Value | Description |
---|---|
0 | None |
1 | Flag resets between 500ms to 5's (default) |
2 / 3 | Flag resets after 2's |
Set Q value to optimize the performance for each environment.
The RFID reader commands tags in an inventory round to choose the random number from 0 to 2^Q. If multiple tags have the same number, tags may not be read successfully because the RFID reader cannot recognize the tag data coming in simultaneously on the same channel.
Larger Q values decrease the probability of collision, but spend more time to read the tags.
Set low if the number of tags is low, and set high if the number of tags is high.
Point Mobile recommends to set 5 when you read multiple tags. |
Set inventory flag of the tag which is going to read.
To improve performance, set A when reading multiple tags, and set A or B when you want to read one tag fast.
Makes the tags, which are read once, quiet to get opportunities to find other tags that not be read. And prevent reading the duplicated tags.
The tags forced to be quiet will wake up when the triggering ends (when the trigger key is up).
|