Setting | Options / Range | Default | Wedge Mode | Result Type | - User Message
- Keyboard Event (Multiple)
- Keyboard Event (Single)
- Clipboard (KEYCODE_PASTE)
- Clipboard (Ctrl + V)
- Custom Intent
| Clipboard (KEYCODE_PASTE) | Custom Intent | Intent Action |
| device.scanner.EVENT | Intent Category |
| android.intent.category.DEFAULT | Extra Decode String Value (String) |
| EXTRA_EVENT_DECODE_VALUE | Extra Decode Bytes Value (ByteArray) |
| EXTRA_EVENT_BYTES_VALUE | Extra Scanner Source (String) |
| EXTRA_EVENT_SOURCE | Character Set | Charset | - UTF-8
- UTF-16
- UTF-16BE
- UTF-16LE
- US-ASCII
- ISO-8859-1
- EUC-KR
- Shift-JIS
- windows-1250
- windows-1251
- windows-1252
- windows-1253
- windows-1254
- windows-1257
| UTF-8 |
|
Setting | Options / Range | Default | Trigger Timeout (sec) | 1 ~ 10 sec | 10 sec | Sleep Timeout (sec) | 1 ~ 60000 sec | 60 sec | Transmit Barcode ID | | Disable | Prefix | Up to 10 characters |
| Suffix | Up to 10 characters |
| Terminator | | LF | Center Window | | Enable | Center Window Tolerance | 0 ~ 100 | 40 | Inverse Mode | - Inverse Off
- Inverse Only
- Inverse AutoDetect
| Inverse Off | HID Inter Char Delays | 0 ~ 250 ms | 20 ms | Batch Mode | - Normal
- Standard mode
- Auto mode
- USB storage mode
| Normal | Deep Sleep Mode | | Disable | Connect Alert | | Enable | Trigger Mode | - Normal
- Enhanced
- Mobile Phone Read
| Normal | Poor Quality 1D Codes Reading | | Disable | Poor Quality PDF Codes Reading | | Disable | Decode Security (Reading Tolerance) | | Medium | Aimer | | Enable | LED Illumination | | Enable | Delay before Decoding (sec) | | Disable | Lock Parameter Barcode Scan | | Disable |
|
Setting | Options / Range | Default | BT Class | | Class 2 | Bluetooth Disconnection Timeout | | None |
|
Setting | Options / Range | Default | Beep | Enable Beep | | Enable | Beep Volume | | High | Power Up Beep | | Enable | Scan Success Beep | | Enable | Scan Fail Beep | | Disable | LED | Enable LED | | Enable | Scan Success LED | | Enable | Scan Fail LED | | Disable |
|
Configuration | Options / Range | Default | Enable | | Enable | ID |
| E | Min |
| 0 | Max |
| 48 | Check Character | - No Check
- Check and Do not transmit
- Check and Transmit
| No Check | Send Start / Stop Characters | | Disable | Full ASCII | | Disable | Append* | | Disable | Code 32 Pharmaceutical | - Disable
- Enable
(Couldn't use with Trioptic)
| Disable | Unconventional InterCharacter Gaps | | Disable | Redundancy* | 0 ~ 10 | 0 |
*If Append mode is enabled, redundancy does not work. |
Configuration | Options / Range | Default | Enable | | Enable | ID |
| I | Send Check Character | | Enable | Addenda Required | | Disable | Send Addenda Separator | | Enable | 2-Digit Addenda | | Disable | 5-Digit Addenda | | Disable | Redundancy | 0 ~ 10 | 0 |
|
Configuration | Options / Range | Default | Enable | | Enable | ID |
| J | Send Check Character | | Enable | Addenda Required | | Disable | Send Addenda Separator | | Enable | 2-Digit Addenda | | Disable | 5-Digit Addenda | | Disable | ISBN Translate | | Disable | Redundancy | 0 ~ 10 | 0 |
|
Configuration | Options / Range | Default | Enable | | Enable | ID |
| ] | Min |
| 1 | Max |
| 80 | Redundancy | 0 ~ 10 | 0 |
|
Configuration | Options / Range | Default | Enable | | Enable | ID |
| P | Redundancy | 0 ~ 10 | 0 |
|
Configuration | Options / Range | Default | Enable | | Enable | ID |
| Q | Redundancy | 0 ~ 10 | 0 |
|
Configuration | Options / Range | Default | Enable | | Enable | ID |
| R | Min |
| 4 | Max |
| 74 | Redundancy | 0 ~ 10 | 0 |
|
Configuration | Options / Range | Default | Enable | | Enable | ID |
| K | Min |
| 4 | Max |
| 80 | Check Character | - No Check
- Check and don't transmit
- Check and transmit
| No Check |
|
Configuration | Options / Range | Default | Enable | | Enable | ID |
| S | Send Check Character | | Enable | Send System Character | | Enable | Addenda Required | | Disable | Send Addenda Separator | | Enable | 2-Digit Addenda | | Disable | 5-Digit Addenda | | Disable | Convert to EAN13 | | Enable | Redundancy | 0 ~ 10 | 0 |
|
Configuration | Options / Range | Default | Enable | | Enable | ID |
| T | Send Check Character | | Disable | Expand | | Enable | Leading Zero | | Enable | Addenda Required | | Disable | Send Addenda Separator | | Enable | 2-Digit Addenda | | Disable | 5-Digit Addenda | | Disable | UPC E1 Enable | | Disable | Redundancy | 0 ~ 10 | 0 |
|
Configuration | Options / Range | Default | Enable | | Disable | ID |
| F | Min |
| 0 | Max |
| 80 | Append* | | Disable | Redundancy* | 0 ~ 10 | 0 |
*If Append mode is enabled, redundancy does not work. |
Configuration | Options / Range | Default | Enable | | Enable | ID |
| A | Min |
| 1 | Max |
| 3832 | Append | | Enable |
|
Configuration | Options / Range | Default | Enable | | Enable | ID |
| H | Min |
| 1 | Max |
| 3166 | Low Contrast Enhancements | - Low Contrast Enhancements Off
- Low Contrast Enhancements On
- Reflective Low Contrast Enhancements On
| Low Contrast Enhancements Off | Append | | Enable |
|
Configuration | Options / Range | Default | Enable | | Enable | ID |
| B | Min |
| 4 | Max |
| 60 | Check Character | - No Check
- Check and don't transmit
- Check and transmit
| No Check | Concatenation | | Disable | Send Start / Stop Characters | | Disable |
|
Configuration | Options / Range | Default | Enable | | Enable | ID |
| O | Min |
| 1 | Max |
| 7089 | Append | | Enable | No Quiet Zone | | Disable |
|
Configuration | Options / Range | Default | Enable | | Disable | ID |
| C | Min |
| 4 | Max |
| 80 | Check Character Required | - One Check Char
- Two Check Char
| Two Check Char | Redundancy | 0 ~ 10 | 0 |
|
Configuration | Options / Range | Default | Enable | | Enable | ID |
| D | Min |
| 0 | Max |
| 80 | Append* | | Enable | Redundancy* | 0 ~ 10 | 0 |
*If Append mode is enabled, redundancy does not work. |
Configuration | Options / Range | Default | Enable | | Disable | ID |
| G | Min |
| 1 | Max |
| 2435 | UPC EAN | | Disable |
|
Configuration | Options / Range | Default | Enable | | Disable | ID |
| L | Min |
| 1 | Max |
| 150 | Message Format | - Primary Message Only
- Primary Required, Secondary if Available
- Both Primary and Secondary Required
| Primary Required, Secondary if Available |
|
Configuration | Options / Range | Default | Enable | | Disable | ID |
| M | Min |
| 1 | Max |
| 366 |
|
Configuration | Options / Range | Default | Enable | | Disable | ID |
| N | Min |
| 1 | Max |
| 2750 | Macro PDF417 | | Enable |
|
Configuration | Options / Range | Default | Enable | | Disable | ID |
| U | Min |
| 4 | Max |
| 48 | Redundancy | 0 ~ 10 | 0 |
|
Configuration | Options / Range | Default | Enable | | Disable | ID |
| V | Min |
| 1 | Max |
| 600 |
|
Configuration | Options / Range | Default | Enable | | Disable | ID |
| W | Min |
| 1 | Max |
| 2048 |
|
Configuration | Options / Range | Default | Enable | | Disable | ID |
| X | Min |
| 4 | Max |
| 48 | Check Character | - Validate Type 10, Don't transmit
- Validate Type 10, Transmit
- Validate 2 Type 10 Chars, Don't transmit
- Validate 2 Type 10 Chars, Transmit
- Validate Type 10 then Type 11 Char, Don't Transmit
- Validate Type 10 then Type 11 Char, Transmit
- No Check Characters
| Validate Type 10, Don't transmit | Redundancy | 0 ~ 10 | 0 |
|
Configuration | Options / Range | Default | Enable | | Disable | ID |
| Y |
|
Configuration | Options / Range | Default | Enable | | Disable | ID |
| Z | Redundancy | 0 ~ 10 | 0 |
|
Configuration | Options / Range | Default | Enable | | Disable | ID |
| [ | Min |
| 4 | Max |
| 80 | Redundancy | 0 ~ 10 | 0 |
|
Configuration | Options / Range | Default | Enable | | Disable | ID |
| \ | Min |
| 1 | Max |
| 60 | Output | | AIM | Redundancy | 0 ~ 10 | 0 |
|
Configuration | Options / Range | Default | Enable | | Disable | ID |
| ^ |
|
Configuration | Options / Range | Default | Enable | | Disable | ID |
| _ | Min |
| 4 | Max |
| 48 | Redundancy | 0 ~ 10 | 0 |
|
Configuration | Options / Range | Default | Enable | | Disable | ID |
| a | Min |
| 1 | Max |
| 7833 |
|
Configuration | Options / Range | Default | Enable | | Disable | ID |
| b | Min |
| 1 | Max |
| 2400 | Poor Quality DotCodes | |
|
|
Configuration | Options / Range | Default | Enable | | Disable | ID |
| c |
|
Configuration | Options / Range | Default | Enable | | Disable | ID |
| d | Min |
| 4 | Max |
| 80 | Redundancy | 0 ~ 10 | 0 |
|
Configuration | Options / Range | Default | Enable | | Disable | ID |
| e | Min |
| 4 | Max |
| 48 | Send Check Character | | Disable |
|
Configuration | Options / Range | Default | Enable | | Disable | ID |
| f | 2D Postal Code | - Australian Post
- InfoMail
- Japanese Post
- KIX Post
- Planet Code
- Postnet
- British Post
- InfoMail and British Post
- Postal-4i
- Intelligent Mail
- Postnet with B and B’ Fields
- Planet Code and Postnet
- Planet Code and Postal-4i
- Postnet and Postal-4i
- Planet Code and Intelligent Mail
- Postnet and Intelligent Mail
- Postal-4i and Intelligent Mail
- Planet Code and Postnet with B and B’ Fields
- Postal-4i and Postnet with B and B Fields
- Intelligent Mail and Postnet with B and B’ Fields
- Planet Code, Postnet, and Postal-4i
- Planet Code, Postnet, and Intelligent Mail
- Planet Code, Postal-4i, and Intelligent Mail
- Postnet, Postal-4i, and Intelligent Mail
- Planet Code, Postal-4i, and Postnet with B and B’ Fields
- Planet Code, Intelligent Mail, and Postnet with B and B’ Fields
- Postal-4i, Intelligent Mail, and Postnet with B and B' Fields
- Planet Code, Postal-4i, Intelligent Mail, and Postnet
- Planet Code, Postal-4i, Intelligent Mail, and Postnet with B and B’ Fields
- Canadian Post
| Australian Post | Australian Post Interpretation | - Bar Output
- Numeric N Table
- Alphanumeric C Table
- Combination N and C Tables
| Bar Output | Send Planet Code Check Character | | Disable | Send Postnet Code Check Charater | | Disable |
|
|
|