ISSUE

  • The device does not charge using a charging cradle



APPLIES TO

All Point Mobile devices




Troubleshooting Steps


CauseSolution
1Extreme
charging temperature

Keep device in normal temperature

Check if the LED blinks in red when you connect charger to the device, it indicates the charging temperature is out of normal.

Charge the device in its charging temperature (usually 0 ~ 45℃).

2The device is not installed
on the cradle properly

Reinstall the device

If the connection between the device and the cradle is not proper, the device may not be charged.

Reinstall the device on the cradle device slot properly.

3Cradle issue

Try with another cradle

Try to charge the device using another cradle. 
If the device is charged properly with new one, the previous cradle may have a problem. Replace the cradle.

4System issue

Perform factory reset

Find the right model from the How to Factory Reset, and perform a factory reset.

5Battery is end-of-life

Replace the battery

(Android 9 and above) Check the battery age from EmKit > EmHealthReport.
If the battery age indicates Warning or Bad (dismission), the battery should be replaced.

Install the new battery and try to charge it again.

6Repair or analysis required

Contact local reseller

If you cannot solve the problem with above steps, contact your local reseller to proceed repair or analyze the issue.