ISSUE

When PM60 WEH scans a barcode starting with '0', the starting 0 is not reading

ex) 0653437XXXXXX → 653437XXXXXX



APPLIES TO

PM60 WEH (Window Mobile)



RESOLUTION

Using Extended Wedge function, add 0 at the start of the decoding data.

Here is the scanner setting which allows you to capture barcode as expected.

Navigate to Settings System > Scanner Settings

Click Wedge tab and enable Enable Extended Wedge check box, and then click Configuration

 

Go to Symbologies under Condition, and then check UPC-A only and click Save

 

Click Add new under Actions

 

Set as below and click Add

  • Action: Send string
  • Value: 0

Check if the result is decoded as expected