67.07 (Apr 30 2024)

Release Notes

VoC

(IMPROVED)

Scan2Set: Improved Scan2Set to allow use of mobile data during provisioning with a QR code.


EmKit

(IMPROVED)

Applied better UX design for the following EmKit solution apps.


Scanner Settings

(NEW)




Added the following settings in the Option menu.

  • DPM enhance mode: reads DPM (Direct Part Marks) better (Only for 2D scanner).
  • Clear Data: removes the currently entered string from the field and enter the newly decoded data.

More> ScanSettings User Guide - Option

Added the Reduced quiet zone option for Interleaved 2 of 5 symbology to read a barcode with narrow quiet zone.


Operating System

(NEW)

Added an ability to calculate the battery lifetime indexes by OS itself.

(IMPROVED)

Improved the date & time setup to perceive the build year after booting or factory reset.

Improved the update operations of the system update app (FOTA client app) when trying to update via intent.

  • Silent update (update without user confirmation)
  • Update while screen is locked

Integrated the battery health information to the EmKit > EmHealthReport instead of the Settings > Battery, for better understanding.





67.05 (Jul 14 2023)

Release Notes

PM67 VoC

(NEW)

EmSettings: 

1) Requested to add notifications when pressing a button on the keypad.

→ Added ability to set key press notification in the EmSettings.

2) Requested to remove the screen rotation button on the navigation bar.

→ Added an option to select whether to use or not the manual screen rotation icon on the navigation bar.

EmKit

(NEW)

System Information: Added radio generation & antenna information in Radio > WLAN section.

Scan2Set: Added ability to use alias for Wi-Fi certificate when provisioning using QR code.

(IMPROVED)

Program Buttons: New smart remap feature and improved UI helps you remap and control the button functions easier.

Scanner / ScanSettings

(NEW)

Added new PEW actions:

  • Change to upper case: Changes all characters to upper case.
  • Change to lower case: Changes all characters to lower case.

Added several scanner settings: 

  • Stop auto scan with scan button: exits the auto scan mode by button.
  • TouchScan size: adjusts the size of the TouchScan button on the screen.
  • Always trigger enable: makes the trigger always turned on.
  • Intercharacter delay: delivers delay time between each character of the decoded data.

Added an option to read a QR code with no quiet zone (low-contrast background) → No Quiet Zone

(IMPROVED)PEW > Send Delay action can be applied between the other actions.


Device Settings

(NEW)

Added new battery health index in Settings > Battery for more accurate battery lifetime estimation.

Added an ability to calculate the battery lifetime indexes by OS itself.

(IMPROVED)

Improved system update (FOTA) to display an error message to check why the update failed.

Network

(NEW)

Added a setting for PNO (Wi-Fi preferred network offload) Scan frequency culling.

(IMPROVED)

Improved the private mobile network setting to have ability to automatic setting.


Operating System

(NEW)

Added ability to allow applications which use CPU resource a lot through Scan2Stage.

(IMPROVED)

System restricts setup wizard proceeding when a provisioning configuration exists in the enterprise storage to wait for the automatic provisioning.

System restricts not display of the power menu when the side scan button and power button are pressed at about the same time. (To prevent inconvenience caused by mis-pressing.)





67.04 (Nov 18 2022)

Release Notes

EmKit

(NEW)

Program Buttons: Meta option for mapping the Ctrl and Shift key combination behavior easily.

(NEW)

EmSettings: Added Hide Navigation setting. Disable to hide the navigation bar on the bottom of the screen.

(IMPROVED)

Direct Clone: Improved backup category name for better understanding of the listed applications

Scanner / ScanSettings

(NEW)

Added IP Send function that sends the barcode data to an IP address through TCP/UDP protocol.

(NEW)

Added new PEW actions, Send up to char / string that send only the part before a specific character or string.

(NEW)

Added new PEW action, Remove back to that trims the last digits of the data.

(NEW)

Added QR Code symbology's detail option, Non square decoding to improve the scan performance when the QR code's finder pattern is slightly out of standard.

(IMPROVED)PEW > Send Next action operates with the length of scanned data automatically when the value you set is longer than the scanned length.
(FIXED)Fixed the issue that the multiple barcode settings are reset when turning the scanner or the device on again.

Device Settings

(NEW)

Added a setting to use a floating action button to show/hide the virtual keyboard

Enterprise Storage

(NEW)

Added availability to custom boot animation using enterprise storage.

(NEW)Added availability to provision with EmInstall.json in enterprise storage

Network

(NEW)

Added a setting for PNO (Wi-Fi preferred network offload) Scan Interval.

(NEW)

Added a setting for selecting band between 2.4GHz and 5GHz for Wi-Fi hotspot (Wi-Fi SKU only)





67.02 (May 03 2022)

  • SDK: v3.24.03
  • Security Patch: 2022-03-05
Release Notes

Find the VoC related to 67.02 version on the below table.

LocationVoCImprovements
KoreaRequested to add a function to restrict USB module connectionAdded API to the system
Also supported through Scan2Stage (From 10.1.2 and compatible client app)
Requested to prevent occurring KeyEvent twice after changing key via KCM file

Improved not to occur keyEvent twice when the key is set as fallback behavior

Related article (Log-in required)

U.S.Requested to remove the File Download dialog during provisioning through Scan2Set

Removed the dialog when the file overwrite checking is not required

EuropeRequested to apply keystroke method when transmitting the decoded data

Optimized the Keyboard Event result type to use the Keystroke method


<New / Improved Functions on PM67 >

Added / Improved Functions

  • [Enterprise Storage] Added a function to reset the enterprise storage
  • [Display] Added All Rotation setting to rotate the screen 180 degree (Default: OFF)
    Related article
  • [EmLogTool] Expanded available log types (see below list) and improved better user experience design
    • Logcat with configurable buffers
    • Kernel message
    • Snapshot
    • Traces
    • QXDM
    • WLAN Driver
    • TCPDump
  • [WLAN]
    • Default band of Wi-Fi hotspot has been changed to 5GHz band
    • Added Privacy setting for using Wi-Fi randomized MAC to enhance network security (Default: Device MAC)
    • Added 5GHz Preference Roaming Functions
  • [Phone] Added private mobile network option for users in private LTE environment
    • Location: Settings > mobile networks > Private mobile network
    • Default: OFF (Not use private LTE)





67.01 (Dec 23 2021)

  • SDK: v3.24.00
  • Security Patch: 2021-11-05
Release Notes

Find the VoC related to 67.01 version on the below table.

LocationVoCImprovements
U.S.

Requested to simplify the QR code provisioning process in Setup Wizard screenProvisioning process will be started once scanning the QR code, without launching Scan2Set manually
Requested to support Enterprise storage

Added /enterprise/usr/ storage which can be used for backup the provisioning data
Related article

Requested a way to identify information that barcode data came fromAdded new intent field, Source of Scanner


<New / Improved Functions on PM67 >

Added / Improved Functions

  • Added LED indication when trying to power on with low battery (Blinking 5 times)
  • (Phone) Added automatic call answer function while Bluetooth (headset) is connected





  • No labels